Extraction of arsenic(III) in aqueous two-phase systems : a new methodology for determination and speciation analysis of inorganic arsenic.

dc.contributor.authorAssis, Roberta C.
dc.contributor.authorFaria, Betania Aparecida de Araujo
dc.contributor.authorCaldeira, Claudia Lima
dc.contributor.authorMageste, Aparecida Barbosa
dc.contributor.authorLemos, Leandro Rodrigues de
dc.contributor.authorRodrigues, Guilherme Dias
dc.date.accessioned2020-06-04T17:31:18Z
dc.date.available2020-06-04T17:31:18Z
dc.date.issued2019
dc.description.abstractThis work utilizes the liquid–liquid extraction technique of aqueous two-phase systems (ATPS) formed by a polymer and electrolyte to develop a novel methodology for the extraction, determination, and speciation analysis of inorganic arsenic. To optimize the methodology, the following parameters were studied: pH of the system, nature of the ATPS-forming electrolyte and the polymer, tie-line length (TLL) of the system, type and concentration of extractants, and the mass ratio of the top and bottom phases. The highest extraction (%E = 98%) was obtained for an ATPS composed of L64 + Na2SO4 + H2O, at pH = 6.00, TLL = 33.55% w/w using the ammonium pyrrolidine dithiocarbamate (APDC) extractant in a molar ratio (APDC/As(III)) of 960, and with a mass ratio of 1/4. In these same conditions, As(V) was not extracted satisfactorily (%E = 18%) to ATPS top phase, with a separation factor equal to 530 after three extractions, showing the great potential of the system for the speciation analysis of inorganic arsenic. Moreover, the method was validated employing HG-ICP OES with a coefficient of determination of 0.9957 and limits of detection and quantification equal to 0.20 μg kg−1 and 0.66 μg kg−1, respectively, proving that the method is capable of detecting the low concentrations required by legislation. The relative standard deviation (RSD) values varied between 4.88 and 9.45%, and the RSD in inter-day precision was 11.07%, which are in accordance with the limits of the validation guide used by the National Institute of Metrology, Quality and Technology, COD-CGCRE-008. Furthermore, relative error rates ranged from −7.44 to 9.90% and recovery percentages were between 92.6 and 110% for the accuracy studies. This method was also applied in a spiked tap water sample, presenting a recovery value equal to 87.10%.pt_BR
dc.identifier.citationASSIS. R. C. et al. Extraction of arsenic(III) in aqueous two-phase systems: a new methodology for determination and speciation analysis of inorganic arsenic. Microchemical Journal, v. 147, p. 429-436, jun. 2019. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0026265X18309251>. Acesso em: 10 fev. 2020.pt_BR
dc.identifier.doihttps://doi.org/10.1016/j.microc.2019.03.058pt_BR
dc.identifier.issn0026-265X
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/12306
dc.identifier.uri2https://www.sciencedirect.com/science/article/pii/S0026265X18309251pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.titleExtraction of arsenic(III) in aqueous two-phase systems : a new methodology for determination and speciation analysis of inorganic arsenic.pt_BR
dc.typeArtigo publicado em periodicopt_BR
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ARTIGO_ExtratcionArsenicAqueous.pdf
Size:
620.9 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
924 B
Format:
Item-specific license agreed upon to submission
Description: