Análise da influência das dimensões de perfurações em perfis formados a frio tipo U enrijecidos sujeitos à flambagem distorcional submetidos à compressão centrada.

dc.contributor.advisorSouza, Flávio Teixeira dept_BR
dc.contributor.advisorSarmanho, Arlene Maria Cunhapt_BR
dc.contributor.authorOliveira, Letícia Caroline Policarpo
dc.contributor.refereeSouza, Flávio Teixeira dept_BR
dc.contributor.refereeSarmanho, Arlene Maria Cunhapt_BR
dc.contributor.refereeAlves, Vinicius Nicchiopt_BR
dc.contributor.refereeRusso, Mário Luís Cabellopt_BR
dc.date.accessioned2021-03-10T19:36:31Z
dc.date.available2021-03-10T19:36:31Z
dc.date.issued2021pt_BR
dc.descriptionPrograma de Pós-Graduação em Engenharia das Construções. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractOs perfis formados a frio apresentam-se como resposta para variados tipos de sistemas estruturais, visto que o desenvolvimento da indústria metálica no mundo torna contínua a busca por estruturas mais leves, econômicas, eficientes e racionais. A elevada relação largura/espessura (esbeltez local) acentua a ocorrência de fenômenos de instabilidade, tais como modos local, distorcional e global, isolados ou em interação, que ocorre quando as cargas críticas coincidem ou apresentam valores próximos. Quando há interação entre esses modos, aumenta-se a complexidade para dar um prognóstico da capacidade de carga e do comportamento do elemento estrutural. Com o crescente uso dos perfis formados a frio, tornase necessário um estudo aprofundado para entender como esses fenômenos interferem na capacidade resistente desse tipo de perfil. O objetivo deste trabalho é avaliar a influência das perfurações na estabilidade e na força axial de compressão resistente dos perfis formados a frio do tipo U enrijecido sujeitos à flambagem distorcional, quando submetidos a uma força de compressão, por meio de métodos numéricos e teóricos adaptados para considerar as perfurações. Na presente pesquisa, foram analisados 4 grupos de perfis U enrijecidos, em cinco situações diferentes: perfil sem furos e com furos de comprimento igual a 20%, 40%, 60% e 80% da largura da alma (bw), sendo eles posicionados a uma distância da aresta alma/flange igual a 20% de bw, espaçados a uma distância de 40% de bw e com largura equivalente a 10% de seu comprimento. Como principais conclusões pode-se ressaltar que o método proposto por Sales apresentou melhores resultados e que não há uma variação expressiva para o valor característico da força axial de compressão resistente para o método de MOEN 2, quando se varia a altura do furo.pt_BR
dc.description.abstractenCold-formed profiles present themselves as an answer to various types of structural systems, since the development of the metal industry in the world makes continuous the search for lighter, more economical, efficient and rational structures. The high width/thickness ratio (local slenderness) accentuates the occurrence of instability phenomena, such as local modes, distortional and global, isolated or in interaction, which occurs when the critical loads coincide or present close values. When there is interaction between these modes, the complexity to provide a prognosis of the load capacity and of the behavior of the structural element increases. With the expanding use of cold-formed profiles, an in-depth study is necessary to understand how these phenomena interfere with the resistant capacity of this type of profile. The objective of this academic work is to evaluate the influence of perforations on the stability and on the resistant axial compressive strength of the C section cold-formed profile type subject to distortion buckling, when subjected to a compressive strength, through numerical and theoretical methods, through numerical and theoretical methods adapted to consider the perforations. In the present study, 4 groups of profiles were analyzed, in five different situations: profiles without holes and with holes equal to 20%, 40%, 60% and 80% of the width of the web (bw), being positioned at a distance from the web/flange edge equal to 20% of bw and spaced at a distance of 40% of bw with a width equivalent to 10% of its length. As main conclusions, it can be emphasized that the method proposed by Sales presented better results and that there is no significant variation for the characteristic value of the axial compressive strength for the MOEN 2 method, when the height of the hole is varied.pt_BR
dc.identifier.citationOLIVEIRA, Letícia Caroline Policarpo. Análise da influência das dimensões de perfurações em perfis formados a frio tipo U enrijecidos sujeitos à flambagem distorcional submetidos à compressão centrada. 2021. 151 f. Dissertação (Mestrado Profissional em Engenharia das Construções) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2021.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/13146
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 04/03/2021 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.pt_BR
dc.subjectConstrução metálicapt_BR
dc.subjectChapas de aço - processo a friopt_BR
dc.subjectFlambagem - mecânicapt_BR
dc.subjectMétodo da resistência direta - MRDpt_BR
dc.titleAnálise da influência das dimensões de perfurações em perfis formados a frio tipo U enrijecidos sujeitos à flambagem distorcional submetidos à compressão centrada.pt_BR
dc.typeDissertacaopt_BR
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
DISSERTAÇÃO_AnáliseInfluênciaDimensões.pdf
Size:
1.55 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
924 B
Format:
Item-specific license agreed upon to submission
Description: