Avaliação das condições físico-construtivas e do desempenho térmico de uma edificação do Instituto Federal do Sudeste de Minas Gerais – estudo de caso.

dc.contributor.advisorRibas, Rovadávia Aline de Jesuspt_BR
dc.contributor.advisorPaula, Geraldo Donizetti dept_BR
dc.contributor.authorBatista, Bruno Cassio Rodrigues
dc.contributor.refereeRibas, Rovadávia Aline de Jesuspt_BR
dc.contributor.refereePaula, Geraldo Donizetti dept_BR
dc.contributor.refereeSilva, Guilherme Jorge Brigolinipt_BR
dc.contributor.refereeGomes, Adriano Pintopt_BR
dc.date.accessioned2018-04-09T16:05:46Z
dc.date.available2018-04-09T16:05:46Z
dc.date.issued2018
dc.descriptionPrograma de Pós-Graduação em Construção Metálica. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractA evolução tecnológica dos materiais de construção, das técnicas de projeto e execução tem proporcionado edificações mais leves, com componentes estruturais mais esbeltos e mais solicitados. No entanto, verifica-se que obras têm sido construídas com grande velocidade e pouco rigor no controle de materiais e serviços, tornando-se relevante o estudo das patologias em edificações existentes visando contribuir para seu desempenho adequado no que se refere à manutenção e durabilidade de seus componentes. Nesse contexto, esse estudo teve como objetivo abordar a concepção estrutural e suas interferências no processo construtivo do galpão construído sobre a Piscina Aquecida do Instituto Federal de Educação, Ciência e Tecnologia do Sudeste de Minas Gerais – Campus Barbacena. A edificação possui pilares e vigas em concreto armado, fechamento externo constituído por alvenaria e cobertura estruturada em aço. Em setembro de 2013, o corpo de bombeiros, junto a um engenheiro mecânico, emitiram um laudo que gerou a interdição da piscina. Por meio de uma investigação exploratória, levantamento fotográfico e coleta de dados, pretende-se fazer um mapeamento a respeito das condições da edificação, identificar as patologias existentes e as causas das mesmas. Nota-se que parte das patologias surgiram devido a erros que ocorreram na concepção da edificação e outras surgiram durante o uso devido à falta de manutenção. Como as aberturas existentes no local não atendem ao mínimo exigido por norma e o fato da piscina ser aquecida, tem-se agravada a eficiência do desempenho térmico. Diante disso, foi feita também uma simulação numérica do desempenho térmico da edificação existente e do projeto para substituição da cobertura, levando em conta as condições de ventilação natural. A partir dos resultados obtidos, pode-se inferir que, a substituição de alguns materiais de fechamento, influencia diretamente no desempenho térmico da edificação. Nesse trabalho procurou-se mostrar a importância da manutenção preventiva, da manutenção corretiva e do desempenho térmico, um dos critérios determinantes do conforto dos usuários.pt_BR
dc.description.abstractenThe technological evolution of building materials, of the design and execution techniques, has provided lighter buildings, with more slender and more requested structural components. Nevertheless, it is verified that works have been constructed with great speed and little rigor in the control of materials and services, becoming relevant the study of the pathologies in existing buildings in order to contribute to their adequate performance with regard to maintenance and durability of their components. In this context, that study had as objective to approach the structural design and its interferences in the constructive process of the shed built over the heated pool of the Federal Institute of Education, Science and Technology of the Southeast of Minas Gerais - Campus Barbacena. The building has pillars and beams in reinforced concrete, external closure constituted by masonry and structured cover in steel. In September 2013, the fire brigade, together with a mechanical engineer, issued an report that led to the ban on the pool. Through an exploratory investigation, photographic survey and data collection, it is intended to make a mapping about the conditions of the building, to identify the existing pathologies and their causes. It is noted that part of the pathologies arose due to errors that occurred in the design of the building and others appeared during the use due to lack of maintenance. As the existing openings do not meet the minimum required by norm and the fact that the pool is heated, it has aggravated the efficiency of thermal performance. Therefore, a numerical simulation of the thermal performance of the existing building and of the project to replace the cover was made, taking into account the conditions of natural ventilation. From the results obtained, it can be inferred that, the substitution of some closing materials, directly influences the thermal performance of the building. In this work, we tried to show the importance of preventive maintenance, of corrective maintenance and thermal performance, one of the criteria that determine the comfort of users.pt_BR
dc.identifier.citationBATISTA, Bruno Cassio Rodrigues. Avaliação das condições físico-construtivas e do desempenho térmico de uma edificação do Instituto Federal do Sudeste de Minas Gerais – estudo de caso. 2018. 84 f. Dissertação (Mestrado Profissional em Construção Metálica) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2018.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/9835
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rightsAn error occurred on the license name.*
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo autor(a), 05/04/2018, com as seguintes condições: disponível sob Licença Creative Commons 4.0, que permite copiar, distribuir e transmitir o trabalho, desde que seja citado o autor e licenciante.pt_BR
dc.rights.uriAn error occurred getting the license - uri.*
dc.subjectConstrução metálicapt_BR
dc.subjectAçopt_BR
dc.titleAvaliação das condições físico-construtivas e do desempenho térmico de uma edificação do Instituto Federal do Sudeste de Minas Gerais – estudo de caso.pt_BR
dc.typeDissertacaopt_BR
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
DISSERTAÇÃO_AvaliaçãoCondiçõesFísico.pdf
Size:
10.74 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
924 B
Format:
Item-specific license agreed upon to submission
Description: