Estudo da viabilidade do método da resistência direta em perfis U enrijecidos formados a frio com perfurações.
dc.contributor.advisor | Souza, Flávio Teixeira de | pt_BR |
dc.contributor.advisor | Sarmanho, Arlene Maria Cunha | pt_BR |
dc.contributor.author | Jardim Júnior, Fausto | |
dc.contributor.referee | Souza, Flávio Teixeira de | pt_BR |
dc.contributor.referee | Sarmanho, Arlene Maria Cunha | pt_BR |
dc.contributor.referee | Alves, Vinicius Nicchio | pt_BR |
dc.contributor.referee | Russo, Mário Luís Cabello | pt_BR |
dc.date.accessioned | 2018-12-17T15:09:17Z | |
dc.date.available | 2018-12-17T15:09:17Z | |
dc.date.issued | 2018 | |
dc.description | Programa de Pós-Graduação em Construção Metálica. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | Os perfis formados a frio são largamente utilizados na construção civil devido sua versatilidade, leveza e resistência. Muitas vezes, para atender a passagem de dutos e soluções estruturais como as ligações dos sistemas de armazenagem industrial, os perfis formados a frio são perfurados. As literaturas normativas atuais não consideram a influência das perfurações na capacidade resistente e no comportamento de perfis formados a frio com perfurações, e a pesquisa sobre o tema ainda é inicial. Em vista disso, é de suma importância estudos e pesquisas que visam consolidar uma base para o dimensionamento de perfis formados a frio com perfurações. O objetivo deste trabalho é a avaliação de extensões de procedimentos normativos para a determinação da força axial resistente de perfis formados a frio de seção U enrijecido, com furos, sob compressão centrada, no âmbito da flambagem distorcional. Foram avaliadas propostas de adaptação do Método da Resistência Direta, previsto em anexo na NBR 14762:2010. Tais avaliações foram feitas realizando estudos numéricos por meio do Método dos Elementos Finitos, com a utilização do programa ANSYS. Inicialmente foi criado um modelo numérico para obter a resistência do perfil U enrijecido, sobre compressão, sem perfurações. Os resultados foram comparados com às prescrições normativas segundo o Método da Resistência Direta para garantir a validade do modelo numérico. Posteriormente, foram introduzidas perfurações no modelo numérico e avaliados os procedimentos de adaptações do Método de Resistência Direta para perfis com furos. Foram avaliados procedimentos propostos por outros pesquisadores, e um procedimento proposto neste trabalho. Os resultados indicaram a viabilidade da adaptação do Método de Resistência Direta para considerar a presença de furos no dimensionamento de perfis formados a frio. | pt_BR |
dc.description.abstracten | The cold-formed steel profiles are widely used in the civil construction due to its versatility, lightness and strength. Often, to acommodate the passage of ducts and structural solutions such as the connections of Industrial Storage Systems, the cold-formed steel profiles are perfurated. The current literature normative does not consider the influence of perfurations on the strength capacity and behavior of cold-formed steel profiles with perforations, and research about the subject is still initial. In view of this, studies and research are extremely important to consolidate a technological base for design procedure of cold-formed steel profiles with perforations. The objective of this research work is the avaluation of adaptations of normative procedures for the determination of the strong axial force of cold-formed profiles C-section, with holes, under centered compression, in the scope of distorcional buckling. Proposals for adaptation of the Direct Strength Method, predicted in the annex in NBR 14762:2010, were evaluated. The numerical studies were performed using the Finite Element Method by means of the software ANSYS. Initially, a numerical model was created to obtain the strength of the profiles C-section, on compression, without perfuration. The results were compared with the normative prescriptions according to the Direct Strength Method to guarantee the validity of the numerical model. Subsequently, were introduced holes in the numerical model and were evaluated the proposals for adaptation of the predicted of the Direct Strength Method. Procedures proposed by previous researchers were evaluated, and a proposed procedure was performed. The results indicated the feasibility of the adaptation of the Direct Strength Method to consider the presence of holes in the design procedure of cold-formed steel profiles. | pt_BR |
dc.identifier.citation | JARDIM JÚNIOR, Fausto. Estudo da viabilidade do método da resistência direta em perfis U enrijecidos formados a frio com perfurações. 2018. 76 f. Dissertação (Mestrado Profissional em Construção Metálica) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2018. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/10594 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 14/12/2018 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação. | pt_BR |
dc.subject | Estruturas metálicas | pt_BR |
dc.subject | Perfis formados a frio | pt_BR |
dc.subject | Flambagem distorcional | pt_BR |
dc.title | Estudo da viabilidade do método da resistência direta em perfis U enrijecidos formados a frio com perfurações. | pt_BR |
dc.type | Dissertacao | pt_BR |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- DISSERTAÇÃO_EstudoViabilidadeMétodo.pdf
- Size:
- 1.26 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 924 B
- Format:
- Item-specific license agreed upon to submission
- Description: