In vivo tests of a novel wound dressing based on biomaterials with tissue adhesion controlled through external stimuli.

dc.contributor.authorIgnacio, Carlos
dc.contributor.authorBarcelos, Luciola da Silva
dc.contributor.authorFerreira, M. D.
dc.contributor.authorMoura, Sandra Aparecida Lima de
dc.contributor.authorSoares, L. A.
dc.contributor.authorOréfice, Rodrigo Lambert
dc.date.accessioned2017-06-23T16:56:08Z
dc.date.available2017-06-23T16:56:08Z
dc.date.issued2011
dc.description.abstractThe high incidence of wounds by second intention and the high costs associated with their treatment give rise to the need for the development of wound dressings that protect not only the wounds themselves but that are also able to promote cell proliferation and skin regeneration. Moreover, it is also very important that no damage to the new regenerated tissue is generated while removing the dressing. In this work, a novel wound dressing, which would be able to favor tissue repair and be removed at an appropriate scheduled moment by means of an external stimulus without promoting extensive damage to the new tissue, was produced and tested. Polyurethane membranes were modified by grafting polymers based on poly(n-isopropylacrylamide) (P-N-IPAAm). P-N-IPAAm undergoes a phase transition at approximately 32 C, which changes its behavior from hydrophilic (below 32 C) to hydrophobic. It was hypothesized that, by reducing the temperature near the wound dressing to values lower than 32 C, the detachment of the dressing would become more effective. The wound dressings containing P-N-IPAAm grafts were tested in vivo by covering excisional wounds produced in mice. The produced dressings were placed in direct contact with the lesions for 3 days. Results showed that the hypothermia due to anesthesia required to remove the dressings from mice lowered the local temperature to 28 C and favored the detachment of the wound dressings containing P-N-IPAAm grafts. Histological analyses showed that lesions covered by dressings presented less intense inflammatory events and denser connective tissue than did the wounds without dressings. The wounds covered by polyurethane membranes with P-N-IPAAm grafts showed signs of more intense re-epithelization and angiogenesis than dipt_BR
dc.identifier.citationIGNACIO, C. et al. In vivo tests of a novel wound dressing based on biomaterials with tissue adhesion controlled through external stimuli. Journal of Materials Science. Materials in Medicine, v. xx, p. 1-8, 2011. Disponível em: <https://link.springer.com/article/10.1007%2Fs10856-011-4299-2>. Acesso em: 20 mar. 2017.pt_BR
dc.identifier.doihttps://doi.org/10.1007/s10856-011-4299-2
dc.identifier.issn1573-4838
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/8061
dc.identifier.uri2https://link.springer.com/article/10.1007%2Fs10856-011-4299-2pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.titleIn vivo tests of a novel wound dressing based on biomaterials with tissue adhesion controlled through external stimuli.pt_BR
dc.typeArtigo publicado em periodicopt_BR
Files