dc.description | Programa de Pós-Graduação em Ciências – Física de Materiais. Departamento de Física, Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | De acordo com relatório da ONU em 2017, o Brasil gerou cerca de 1,4 106 t de resíduos de equipamentos elétricos e eletrônicos – REEE (ABRIN, 2017), sendo cerca de 23% deste resíduo, material plástico. A legislação que orienta a gestão de resíduos sólidos (Lei nº 12.305 de 2010), sendo nova, ainda tem pendência de acordos setoriais com o setor produtivo e varejista, assim, o Ministério da Ciência, Tecnologia, Inovações e Comunicações - MCTIC patrocina a rede de Centros de Recondicionamento de Computadores – CRC’s, sendo estes, espaços para o tratamento de equipamentos obsoletos ou inservíveis, podendo ser recondicionados ou ter suas partes destinadas à indústria de reciclagem. O CRC Programando o Futuro de Valparaíso/GO produz blocos intertravados a partir de carcaças e componentes plásticos para aplicação em pavimentos, passadiços, passarelas elevadas e estacionamento. O objetivo deste trabalho é a caracterizar e analisar as propriedades mecânicas que se relacionam com a aplicação desses blocos, estimar a incerteza associada a cada ensaio utilizando o método da Norma ISO GUM e elaborar roteiro para garantir a confiabilidade de resultados durante atividades laboratoriais. A metodologia indicada nas normas para os respectivos ensaios não contemplam alguns geradores de incerteza de medição, como por exemplo a incerteza herdada da calibração dos equipamentos utilizados. Os resultados dos ensaios dos blocos de REEE são comparáveis aos parâmetros de blocos de concreto comumente utilizados em aplicações similares, por exemplo, para a resistência à compressão em temperatura ambiente obteve-se (41 ± 5) MPa e taxa de absorção de (0,0846±0,0002) % no bloco intertravado de REEE. O uso normalizado de resistência à compressão é maior ou igual a 35 MPa e a absorção menor ou igual a 6 %, de acordo com a ABNT NBR 9781:2013. Esta pesquisa foi realizada com o apoio da Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES): Código de financiamento 001. Os ensaios foram realizados no Laboratório de Mecânica de Fratura DEMET/EM/UFOP. | pt_BR |
dc.description.abstracten | According to a ONU report in 2017, Brazil generated about 1.4 106 t of waste electrical and electronic equipment - WEEE (ABRIN, 2017), with around 23% of this waste being plastic material. The legislation that guides the management of solid waste (Law No. 12,305 of 2010), being new, is still pending sectorial agreements with the productive and retail sector, thus, the Ministry of Science, Technology, Innovations and Communications - MCTIC sponsors the network of Computer Reconditioning Centers - CRC's, which are spaces for the treatment of obsolete or useless equipment, which can be reconditioned or have their parts destined to the recycling industry. CRC Programming the Future of Valparaíso / GO produces interlocking blocks from carcasses and plastic components for application on floors, walkways, elevated walkways and parking. The objective of this work is to characterize and analyze the mechanical properties that are related to the application of these blocks, to estimate the uncertainty associated with each test using the method of the ISO GUM Standard and to elaborate a script to guarantee the reliability of results during laboratory activities. The methodology indicated in the standards for the respective tests does not include some generators of measurement uncertainty, such as the uncertainty inherited from the calibration of the equipment used. The results of the WEEE block tests are comparable to the concrete block parameters commonly used in similar applications, for example, for compressive strength at room temperature (41 ± 5) MPa and absorption rate of (0, 0846 ± 0.0002)% in the WEEE interlocked block. The standardized use of compressive strength is greater than or equal to 35 MPa and the absorption is less than or equal to 6%, according to ABNT NBR 9781: 2013. This research was carried out with the support of the Coordination for the Improvement of Higher Education Personnel - Brazil (CAPES): Financing code 001. The tests were performed at the DEMET / EM / UFOP Fracture Mechanics Laboratory. | pt_BR |
dc.identifier.citation | GABRIEL, Luiz Tadeu. Caracterização de bloco intertravado manufaturado a partir de resíduo de eletroeletrônicos com análise dos procedimentos e metodologia metrológica dos ensaios. 2020. 189 f. Dissertação (Mestrado em Ciências – Física de Materiais) – Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto, Ouro Preto, 2020. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/12341 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 04/06/2020 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite a adaptação. | pt_BR |
dc.subject | Lixo eletrônico - reaproveitamento | pt_BR |
dc.subject | Produtos reciclados | pt_BR |
dc.subject | Causalidade - física | pt_BR |
dc.title | Caracterização de bloco intertravado manufaturado a partir de resíduo de eletroeletrônicos com análise dos procedimentos e metodologia metrológica dos ensaios. | pt_BR |
dc.type | Dissertacao | pt_BR |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- DISSERTAÇÃO_CaracterizaçãoBlocoIntertravado.pdf
- Size:
- 8.65 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 924 B
- Format:
- Item-specific license agreed upon to submission
- Description: